Midmark Ritter M9 Autoclave, Gen 1, good working condition with 30 day parts and labor warranty
Couldn't load pickup availability
How the Ritter M9 Automatic Autoclave works:
Simply press the Start/Standby button and this autoclave will fill itself with the appropriate amount of water automatically. Once the autoclave is filled with water, select your cycle and the M9 will set the time for you. Cycle time from start to finish is 22 minutes (if cold) and 12 minutes (if hot).
Features and Benefits:
- Low water indicator light tells you when the reservoir level is too low
- A door-ajar light tells you if the door is not securely closed
- LED display shows the units temperature during heat-up and time remaining during cycles.
- Lights turn on progressively during filling, heating, sterilizing, drying and complete stages.
- Easy to fill and to drain water - located at the front of the machine
- A large capacity water reservoir means you fill it less often!
- Four stainless steel trays come with the unit (two large, two small)
- Easy-to-read pressure gauge and electronic controls offer simple operation and reduce down time
About Good-Working autoclaves at Duraline:
In response to customer demand, Duraline has released autoclaves in good-working condition as a less expensive alternative to new or fully refurbished sterilizers. Good working units may have cosmetic defects and only include 30 day parts and labor warranty. For long-term, used autoclaves that look and function like new we recommend our refurbished sterilizers.
- Chamber Size: 9" x 15"
- Volume: 3.5 gal (13.4 L)
- Dimensions (L x W x H): 20.4" x 15.3" x 15.38"
- Trays: 4
- Tray Size (L x W x H): Two Large: 7.3" W x 12" L x 0.8" D & Two Small: 5.6" W x 12" L x 0.8" D
- Standard Unwrapped Cycle Time: Cold: 30 Min & Hot: 14 min
- Voltage: 115V
- Frequency: 50/60
- Current: 15A
- Shipping Weight: 81 lbs
- Minimum Countertop Area: 15.3" W x 17.9" D
| Sterilization Programs | Temp. | Hot Cycle Time (fill, heat-up & vent) | Sterilization Time | Dry Time | Total Hot Cycle Time (without dry) |
Total Hot Cycle Time (with dry) | |
| Description | Icon | ||||||
| Unwrapped |
|
270° F | 11 min | 3 min | 30 min | 14 min | 44 min |
| Pouches |
![]() |
270° F | 12 min | 5 min | 30 min | 17 min | 47 min |
| Packs |
![]() |
250° F | 10 min | 30 min | 30 min | 40 min | 70 min |
| Handpieces |
![]() |
270° F | 11 min | 6 min | 30 min | 17 min | 47 min |
Midmark / Ritter M9 Ultraclave, Old Style Operators Manual
Approvals:
- Meets the requirements of ASME Boiler and Pressure Vessel Code
- UL Listed to U.S. & Canadian Standards
Midmark Ritter M9 Autoclave, Generation 1, good working condition with 30-day parts and labor warranty How the Ritter M9 Automatic Autoclave works: Simply press the Start/Standby button and this autoclave will fill itself with the appropriate amount of water automatically.
Good working units may have cosmetic defects and only include 30 day parts and labor warranty.
WARRANTY: 30 days parts and labor