Skip to content

Free Shipping on Orders Over $3000

RapidHeat RH-Pro9 High Velocity Hot Air Sterilizer

RapidHeat RH-Pro9 High Velocity Hot Air Sterilizer

Regular price
Sale price $6,740.00 Regular price $7,040.00
REBATE SALE: RapidHeat RH-Pro Sterilizer from Now to June 30, 2026 - Click for Rebate Form


New RapidHeat RH-Pro9 HVHA Hot Air Sterilizer, 3-Tray Compact, 110-120V

Product Code: NRH-PRO9


The perfect replacement for the now discontinued Dentronix Sterilizer. Accommodates Dentronix plier racks!


Chamber air circulates at over 200 times per minute! Watch how it works in Video tab.

The Industry’s Most Efficient Sterilizer (now in a convenient cabinet-ready size)
Chamber air circulates at over 200 times per minute!

The RapidHeat RH-Pro9 High Velocity Hot Air Sterilizer brings advanced “RapidCycle” sterilization into a compact, cabinet-ready footprint. Utilizing HVHA (High-Velocity Hot Air) technology, it achieves FDA-cleared cycles in as little as 6 minutes unwrapped and 12 minutes wrapped. Designed as a replacement for discontinued Dentronix sterilizers, it accommodates existing plier racks while eliminating water, steam, and drying cycles. With air circulating over 200 times per minute, the RH-Pro9 improves workflow efficiency, reduces energy consumption, and provides a non-corrosive sterilization environment.

For Healthcare, the RH-Pro9 can Eliminate Immediate-Use Steam Sterilization, shortened cycles, work-arounds, and Joint Commission scrutiny!

The RH-Pro9 Advantage
  • FDA-Cleared 6 Minute Cycles (Unwrapped)
  • FDA-Cleared 12 Minute Cycles (Wrapped)
  • Smaller Cabinet-Ready Size (1163 Cubic Inches)
  • Uses 85% Less Energy Than Steam
  • Non-Corrosive Sterilizer Environment
  • Full 3-Year Warranty
  • Waterless Sterilization with No Chemicals
  • Convenient Smaller Size -- Three Instrument Trays
  • Available in 2 sizes:
    • RH-Pro9 - 3 trays / chamber: 9.5”W x 15.6”D x 7.85”H
    • RH-Pro11 - 4 trays / chamber: 11”W x 17.75”D x 11.75”H


Compare RapidHeat vs. Steam Sterilization

Sterilizer Feature RapidHeat Steam
Start to Finished Sterilization Cycle 12-20 minutes 61-116 minutes
Sterilizer Operation
Simple Complex
Water Requirements None Distilled Water
FDA 510(k) Cleared Yes Yes
Cycle Documentation Yes Yes
Instrument Drying Cycle None FDA Required
Potential for Instrument Corrosion None High
Energy Use (kWh/cycle) $0.11/cycle $0.74/cycle
Maintenance and Repair Cost $0.80/cycle $6.00/cycle

Notes:
Start to finish cycle represents the time range for sterilizing unwrapped, pouched and wrapped (cassette/tray) instruments from cold start to finish (includes dry cycle for steam).
Sterilizer Operation reflects the level of sterilizer preparation and management for instrument processing.

Potential for instrument Corrosion is absent in the dry environment pf a RapidHeat sterilizer and high for instruments in a steam environment.

Energy Use represents kilowatts of power used per hour when operating a sterilizer cycle. This study was conducted by the Rochester Institute of Technolofy comparing RapidHeat to 2 popular tabletop steam sterilizers.

Maintenance and Repair Cost is based on actual reported costs and estimated over useful life.

WARRANTY: 3 year parts & labor