RapidHeat RH-Pro9 High Velocity Hot Air Sterilizer
Couldn't load pickup availability
New RapidHeat RH-Pro9 HVHA Hot Air Sterilizer, 3-Tray Compact, 110-120V
Product Code: NRH-PRO9
The perfect replacement for the now discontinued Dentronix Sterilizer. Accommodates Dentronix plier racks!
Chamber air circulates at over 200 times per minute! Watch how it works in Video tab.
The Industry’s Most Efficient Sterilizer (now in a convenient cabinet-ready size)
Chamber air circulates at over 200 times per minute!
The RapidHeat RH-Pro9 High Velocity Hot Air Sterilizer brings advanced “RapidCycle” sterilization into a compact, cabinet-ready footprint. Utilizing HVHA (High-Velocity Hot Air) technology, it achieves FDA-cleared cycles in as little as 6 minutes unwrapped and 12 minutes wrapped. Designed as a replacement for discontinued Dentronix sterilizers, it accommodates existing plier racks while eliminating water, steam, and drying cycles. With air circulating over 200 times per minute, the RH-Pro9 improves workflow efficiency, reduces energy consumption, and provides a non-corrosive sterilization environment.
For Healthcare, the RH-Pro9 can Eliminate Immediate-Use Steam Sterilization, shortened cycles, work-arounds, and Joint Commission scrutiny!
The RH-Pro9 Advantage
- FDA-Cleared 6 Minute Cycles (Unwrapped)
- FDA-Cleared 12 Minute Cycles (Wrapped)
- Smaller Cabinet-Ready Size (1163 Cubic Inches)
- Uses 85% Less Energy Than Steam
- Non-Corrosive Sterilizer Environment
- Full 3-Year Warranty
- Waterless Sterilization with No Chemicals
- Convenient Smaller Size -- Three Instrument Trays
- Available in 2 sizes:
Compare RapidHeat vs. Steam Sterilization
Start to finish cycle represents the time range for sterilizing unwrapped, pouched and wrapped (cassette/tray) instruments from cold start to finish (includes dry cycle for steam).
Sterilizer Operation reflects the level of sterilizer preparation and management for instrument processing.
Potential for instrument Corrosion is absent in the dry environment pf a RapidHeat sterilizer and high for instruments in a steam environment.
Energy Use represents kilowatts of power used per hour when operating a sterilizer cycle. This study was conducted by the Rochester Institute of Technolofy comparing RapidHeat to 2 popular tabletop steam sterilizers.
Maintenance and Repair Cost is based on actual reported costs and estimated over useful life.
- Overall Dimensions: 19.6" W x 17.5" D x 13.3" H (498 mm x 445 mm x 338 mm)
- Chamber Size: 9.5”W x 15.6”D x 7.85”H (241mm x 396mm x 199mm)
- Weight: 60 lbs
- Instrument Tray: 7.3”W x 12”D x 0.85”H
- Electrical: 110-120V, 60Hz, 1400 Watts warm up, 300 Watts operating / 220-240V, 50Hz, 1400 Watts warm up, 200 Watts operating
- Sterilization Temperature: 375º Fahrenheit (190º Celsius)
- Warranty: 3 years parts and labor
- Safety: Meets Requirements of U.S. Electrical Safety Standards

Q. What are the cycle times for the RH-Pro9?
A. FDA-cleared cycles of 6 minutes (unwrapped) and 12 minutes (wrapped).
Q. Is it suitable for small spaces or cabinetry?
A. Yes, the RH-Pro9 is designed as a compact, cabinet-ready sterilizer.
Q. Does the RH-Pro9 require water or steam?
A. No, it uses HVHA technology for completely waterless sterilization.
Q. Does it require a drying cycle?
A. No, instruments come out dry since no steam or moisture is used.
Q. Can I use the same pouches as my autoclave?
A. No. RapidHeat sterilizers reach up to 375°F, and most steam pouches cannot withstand this heat.
Q. Can instruments be wet when loaded?
A. No. Instruments must be completely dry. Any liquid can produce steam inside the chamber.
View preparation guide.
Q. Can it replace a Dentronix sterilizer?
A. Yes, it is designed as a replacement and accommodates Dentronix plier racks.
Q. Can I use existing Dentronix plier racks?
A. Yes. View IFU.