Other options
- New Midmark Gen 5 model (050)
- Refurbished M11 (042)
New Midmark Ritter M9D Autoclave, Current Model -042 Gen 3
Sterilization is made easy by the Midmark Ritter M9 Ultraclave Autoclave. Simply press the Start/Standby button and this autoclave will fill itself with the appropriate amount of water automatically. Once the autoclave is filled with water, select your cycle and the M9 will set the time for you. Cycle time from start to finish is 22 minutes (if cold) and 12 minutes (if hot).
What makes the Midmark M9D different than the
M9 model?
The door on the M9D has to manually be opened
after the sterilization cycle to being drying. The door on the M9 and M11
automatically "pops" open to let steam out when the sterilization
cycle is complete.
Features:
- Low water indicator light tells you when the reservoir level is too low
- A door-ajar light tells you if the door is not securely closed
- LED display shows the units temperature during heat-up and time remaining during cycles.
- Lights turn on progressively during filling, heating, sterilizing, drying and complete stages.
- Easy to fill and to drain water - located at the front of the machine
- A large capacity water reservoir means you fill it less often!
- Four stainless steel trays come with the unit (two large, two small)
- Easy-to-read pressure gauge and electronic controls offer simple operation and reduce down time
- Chamber Size: 9" x 15"
- Volume: 3.5 gal (13.4 L)
- Dimensions (L x W x H): 20.4" x 15.3" x 15.38"
- Trays: 4
- Tray Size (L x W x H): Two Large: 7.3" W x 12" L x 0.8" D & Two Small: 5.6" W x 12" L x 0.8" D
- Standard Unwrapped Cycle Time: Cold: 30 Min & Hot: 14 min
- Voltage: 115V
- Frequency: 50/60
- Current: 15A
- Shipping Weight: 81 lbs
- Minimum Countertop Area: 15.3" W x 17.9" D
| Sterilization Programs | Temp. | Hot Cycle Time (fill, heat-up & vent) | Sterilization Time | Dry Time |
Total Hot Cycle Time (without dry) |
Total Hot Cycle Time (with dry) | |
| Description | Icon | ||||||
| Unwrapped |
|
270° F | 11 min | 3 min | 30 min | 14 min | 44 min |
| Pouches |
![]() |
270° F | 12 min | 5 min | 30 min | 17 min | 47 min |
| Packs |
![]() |
250° F | 10 min | 30 min | 30 min | 40 min | 70 min |
| Handpieces |
![]() |
270° F | 11 min | 6 min | 30 min | 17 min | 47 min |
Midmark Ritter M9D Steam Sterilizer Technical Specifications (-040 / -041 / -042)
Midmark Ritter M9D Steam Sterilizer Care Guide
Approvals:
- Meets the requirements of ASME Boiler and Pressure Vessel Code
- UL Listed to U.S. & Canadian Standards
The door on the M9D has to manually be opened after the sterilization cycle to being drying. The door on the M9 and M11 automatically "pops" open to let steam out when the sterilization cycle is complete.
it less often! Four stainless steel trays come with the unit (two large, two small) Easy-to-read pressure gauge and electronic controls offer simple operation and reduce down time WARRANTY: 12 months parts only