RapidHeat RH-Pro11 High-Velocity Hot Air Sterilizer
Couldn't load pickup availability
New RapidHeat RH-Pro11 High-Velocity Hot Air Sterilizer, 110-120V or 220-240V
Product Code: NRH-PRO11
The perfect replacement for the now discontinued Dentronix Sterilizer. The RH-Pro11 even accommodates Dentronix plier racks!
Read RapidHeat Sterilizers: The perfect replacement for the now discontinued Dentronix sterilizers
Chamber air circulates at over 200 times per minute! Watch how it works in Video tab.
The RapidHeat RH-Pro11 High-Velocity Hot Air Sterilizer delivers advanced “RapidCycle” sterilization using HVHA technology, achieving FDA-cleared cycles as fast as 6 minutes unwrapped and 12 minutes wrapped. Designed as a direct replacement for discontinued Dentronix sterilizers, it accommodates existing plier racks while eliminating water, steam, and corrosion risks. With a large 4-tray capacity and over 200 air circulations per minute, the RH-Pro11 improves instrument turnaround, reduces energy consumption, and simplifies sterilization workflows without drying cycles or chemicals.
View How to Wrap and Tape Cassettes for RapidHeat Sterilizers
The RapidHeat Sterilizer Advantage:
- FDA-Cleared 6 Minute Cycles (Unwrapped)
- FDA-Cleared 12 Minute Cycles (Wrapped)
- Large Table-Top Capacity (2295 Cubic Inches)
- Uses 85% Less Energy Than Steam
- Non-Corrosive Sterilizer Environment
- Full 3-Year Warranty
- Waterless Sterilization with No Chemicals
- Greater Capacity -- Four Large Trays
- Handles Small and Large Cassettes
- Available in 2 sizes:
Compare RapidHeat vs. Steam Sterilization
Notes:
Start to finish cycle represents the time range for sterilizing unwrapped, pouched and wrapped (cassette/tray) instruments from cold start to finish (includes dry cycle for steam).
Sterilizer Operation reflects the level of sterilizer preparation and management for instrument processing.
Potential for instrument Corrosion is absent in the dry environment pf a RapidHeat sterilizer and high for instruments in a steam environment.
Energy Use represents kilowatts of power used per hour when operating a sterilizer cycle. This study was conducted by the Rochester Institute of Technology comparing RapidHeat to 2 popular tabletop steam sterilizers. Maintenance and Repair Cost is based on actual reported costs and estimated over useful life.
- Chamber Size: 11”W x 17.75”D x 11.75”H
- Outside Dimensions (LxWxH): 22.5" W x 22.5" D x 19.5" H
- Trays: 4
- Tray Size: 9”W x 15”D x 1”H
- Weight: 75 lbs
- Voltage (V) - Frequency (Hz) :110-120V, 60Hz, 1400 Watts warm up, 300 Watts operating
- Voltage (V) - Frequency (Hz) :220-240V, 50Hz, 1400 Watts warm up, 300 Watts operating

RapidHeat Product Brochure
RH-Pro11 Brochure
RH-Pro11 Flyer
RH-Pro11 Operator Manual
How to Wrap and Tape Cassettes for RapidHeat Sterilizers
How to Prepare Instruments for RapidHeat Sterilization
Dentronix Plier Rack IFU
Q. What cycle times does the RH-Pro11 offer?
A. FDA-cleared cycles include 6 minutes (unwrapped) and 12 minutes (wrapped).
Q. Does the RH-Pro11 require water or steam?
A. No, it uses HVHA technology for completely waterless, dry sterilization.
Q. Does it require a drying cycle?
A. No, instruments come out dry since no steam or moisture is used.
Q. Can I use the same pouches as my autoclave?
A. No. RapidHeat sterilizers reach up to 375°F, and most steam sterilization pouches cannot withstand this heat.
Q. Can instruments be loaded wet?
A. No. Instruments must be completely dry. Any liquid will produce steam inside the chamber.
View preparation guide.
Q. Can it replace a Dentronix sterilizer?
A. Yes, it is designed as a direct replacement and accommodates Dentronix plier racks.
Q. Can I continue using Dentronix plier racks?
A. Yes. See IFU.