Self-Contained Spore Ampoules to Monitor Liquid Steam Sterilization, Log 5 spore population
Important: This item must be shipped UPS OVERNIGHT on ice packs
Size: 47mm X 10.6mm x 1ml (volume)
50 per box
Biological indicators can be used in Steam Autoclaves at 121°C to 137°C for monitoring liquid steam processes and dry loads. Must be used with Bionova IC10/20 incubator, sold at Duraline BioSystems, Inc. For laboratory or industrial use only.
Note: Spore ampoules must be kept refrigerated and ship overnight. These are specially made for monitoring liquid sterilization in steam autoclaves.
Call for quantity discounts 877-561-0500
Instructions for Use
Place Mini Spore Ampules inside representative materials (containers of liquid) or within the autoclave chamber directly. Package or wrap product as usual, if applicable. Locate product or Mini Spore Ampules in most difficult location to sterilize, as outlined in your specific sterilization validation protocol or according to standard operating procedure. Run the cycle. After sterilization or exposure, remove Mini Spore Ampules or product from sterilizer. Allow product or Spore Ampules to cool to the touch. No activation is required.
Incubation: Place the processed Mini Spore Ampules, one Negative Control Ampule and one Positive Control (unprocessed Mini Spore Ampule) in a vertical position in an incubator at 60°C to 65°C for a minimum of 48 hours.
Monitoring: Examine the Mini Spore Ampules daily during incubation. Record observations. All positive Mini Spore Ampules should be disposed of immediately. Do not continue to incubate a positive Ampule. Continued growth may result in metabolism of amino acids in the absence of sugars, causing the pH to rise and result in color reversion that is visibly darker than a sterile unit. These should be considered as positive for growth (turbidity will be present).
Interpretation: Negative Control: The Negative Control Ampule should not exhibit a color change to Yellow and/or demonstrate turbidity. Utilize the Negative Control as a color comparison for the exposed Mini Spore Ampules, where applicable.
Positive Control Mini Spore Ampule: The Positive Control Ampule should exhibit a color change to Yellow and/or demonstrate turbidity. Utilize the Positive Control as a color comparison for the exposed Ampules, where applicable. If the positive control does not demonstrate a Yellow color and/or turbidity, the results for the test Ampules should not be considered valid. Verify incubation conditions were met.
Test Mini Spore Ampules: A passing sterilization cycle is indicated by a test Spore Ampule which retains its original Purple color and is free from turbidity. A failed sterilization cycle is indicated by turbidity and/or a color change to Yellow.
For unexpected positives, it is recommended that a Gram stain be performed. Gram positive rods are indicative for the indicator organism.
Important: This item must be shipped UPS OVERNIGHT on ice packs
Size: 47mm X 10.6mm x 1ml (volume)
50 per box
Biological indicators can be used in Steam Autoclaves at 121°C to 137°C for monitoring liquid steam processes and dry loads. Must be used with Bionova IC10/20 incubator, sold at Duraline BioSystems, Inc. For laboratory or industrial use only.
Note: Spore ampoules must be kept refrigerated and ship overnight. These are specially made for monitoring liquid sterilization in steam autoclaves.
Call for quantity discounts 877-561-0500
Instructions for Use
Place Mini Spore Ampules inside representative materials (containers of liquid) or within the autoclave chamber directly. Package or wrap product as usual, if applicable. Locate product or Mini Spore Ampules in most difficult location to sterilize, as outlined in your specific sterilization validation protocol or according to standard operating procedure. Run the cycle. After sterilization or exposure, remove Mini Spore Ampules or product from sterilizer. Allow product or Spore Ampules to cool to the touch. No activation is required.
Incubation: Place the processed Mini Spore Ampules, one Negative Control Ampule and one Positive Control (unprocessed Mini Spore Ampule) in a vertical position in an incubator at 60°C to 65°C for a minimum of 48 hours.
Monitoring: Examine the Mini Spore Ampules daily during incubation. Record observations. All positive Mini Spore Ampules should be disposed of immediately. Do not continue to incubate a positive Ampule. Continued growth may result in metabolism of amino acids in the absence of sugars, causing the pH to rise and result in color reversion that is visibly darker than a sterile unit. These should be considered as positive for growth (turbidity will be present).
Interpretation: Negative Control: The Negative Control Ampule should not exhibit a color change to Yellow and/or demonstrate turbidity. Utilize the Negative Control as a color comparison for the exposed Mini Spore Ampules, where applicable.
Positive Control Mini Spore Ampule: The Positive Control Ampule should exhibit a color change to Yellow and/or demonstrate turbidity. Utilize the Positive Control as a color comparison for the exposed Ampules, where applicable. If the positive control does not demonstrate a Yellow color and/or turbidity, the results for the test Ampules should not be considered valid. Verify incubation conditions were met.
Test Mini Spore Ampules: A passing sterilization cycle is indicated by a test Spore Ampule which retains its original Purple color and is free from turbidity. A failed sterilization cycle is indicated by turbidity and/or a color change to Yellow.
For unexpected positives, it is recommended that a Gram stain be performed. Gram positive rods are indicative for the indicator organism.
Technical Specifications
| Process | Steam |
|---|---|
| Loads | Liquid and Dry loads |
| Spore Population | Log 5 spore population |
| Size | 47mm X 10.6mm |
| Volume | 1ml |
| Quantity | 50 per box |
| Temperature Range | 121°C to 137°C |
| Incubator | Bionova IC10/20 |
Storage Note: Spore ampoules must be kept refrigerated and ship overnight. This item must be shipped UPS OVERNIGHT on ice packs.
Mini-Spore Ampules Log 5 BI-MSA-ATM05 Technical Data Sheet
Compliance:
ISO 11138-1 Sterilization of health care products - Biological indicators - Part 1: General requirements
ISO 11138-3 Sterilization of healthcare products - Biological indicators - Part 3: Biological indicators for moist heat sterilization processes.
USP <55> Biological Indicators - Resistance Performance Tests
True Indicating has a validated method for Total Viable Spore Count. Please inquire for the Technical Bulletin which outlines the recommended methodology.
Compliance:
ISO 11138-1 Sterilization of health care products - Biological indicators - Part 1: General requirements
ISO 11138-3 Sterilization of healthcare products - Biological indicators - Part 3: Biological indicators for moist heat sterilization processes.
USP <55> Biological Indicators - Resistance Performance Tests
True Indicating has a validated method for Total Viable Spore Count. Please inquire for the Technical Bulletin which outlines the recommended methodology.
FAQ
Scroll down for frequently asked questions
Scroll down for frequently asked questions
| Image | Product Code | Description | Spore Population | Size | Volume | Quantity | Price/box | View |
![]() | BI-MSA-ATM05 | Mini Spore Ampule | Log 5 | 40mm x 6.5mm diam | 0.7ml | 50/box | $220 | Add To Cart |
![]() | BI-MSA-ATM06 | Mini Spore Ampule | Log 6 | 40mm x 6.5mm diam | 0.7ml | 50/box | $220 | Add To Cart |
![]() | BI-SA-L4 | Spore Ampule | Log 4 | 47mm x 10.6mm | 1ml | 50/box | $220 | Add To Cart |
![]() | BI-SA-L5 | Spore Ampule | Log 5 | 47mm x 10.6mm | 1ml | 50/box | $320 | Add To Cart |
![]() | BI-SA-L6 | Spore Ampule | Log 6 | 47mm x 10.6mm | 1ml | 50/box | $339 | Add To Cart |
Explore Our FAQs for Helpful Answers
Find answers to common questions about this product, including features, specifications, and operation. Need more help? Our team is here to assist.
What are these ampoules for?
What are these ampoules for?
Monitoring liquid steam sterilization processes and dry loads in steam autoclaves at 121°C to 137°C. For laboratory or industrial use only.
Does the ampoule need to be activated?
Does the ampoule need to be activated?
No activation is required. After the cycle, let the ampoules cool to the touch and place them in the incubator.
Which incubator do I need?
Which incubator do I need?
The Bionova IC10/20 incubator. Incubate processed ampoules, one Negative Control and one Positive Control upright at 60°C to 65°C for a minimum of 48 hours.
How do I read the results?
How do I read the results?
A passing cycle keeps the original purple color with no turbidity. A failed cycle shows turbidity and/or a color change to yellow.
Why does it ship overnight on ice packs?
Why does it ship overnight on ice packs?
Spore ampoules must be kept refrigerated, so this item must be shipped UPS overnight on ice packs.