Bionova MiniBio Auto-Reader Starter Kit with Ultra Rapid Biological Indicators, 20 Minute Results
Couldn't load pickup availability
MINIBIO Auto-Reader Incubator for Biological Indicators with 3 positions and built-in printer, with Ultra-Rapid Biological Indicators, 20 Minute results for Steam, Starter KIt
Product code: BI-BMBAR20-SK
Included with Kit:
For the incubation and automatic readout of Rapid, Super Rapid and Ultra Rapid Self-contained biological indicator (SCBIs) appropriate for sterilization and environmental disinfection process control applications.
MiniBio Auto-Reader Incubator Features:
-
Multi-Indicator Compatibility: Accommodates various Bionova / Tuttnauer Biological Indicators for comprehensive testing.
- 20 Minute & 1 hour process times can be used simultaneously
- Versatile Incubation: Three metal positions for simultaneous incubation of different indicators at customizable temperatures. (3 Incubation slots)
- Efficient Readout: Rapid, Super Rapid, and Ultra Rapid Fluorescence Readout options for swift results.
-
User-Friendly Design: Self-contained biological indicators and USB connectivity for easy result registration.
- Operating Specifications: Input 100/240V 0.2A (50/60Hz)/Output: 12V 4A
-
Dual Temperature System: Selectable between 37ºC and 60ºC for optimal indicator performance.
- Working Temperature: 37 ± 2°C, 60 ± 2°C
- Integrated Safety Features: Sound alarm, automatic cancellation of fluorescence reading, and event indication.
- Compact and Convenient: Dimensions of 180mm x 154mm x 105mm for space-saving efficiency.
- Upgradable Firmware: User-friendly firmware update capability for future enhancements.
Bionova Ultra Rapid Biological Indicators Features
-
Rapid Results:
- 20-minute readout time for quick sterilization process feedback.
-
High Spore Concentration:
- Contains Geobacillus Stearothermophilus (ATCC® 7953) spores at 10^6 spores per vial.
-
Optional Visual pH Confirmation:
- pH color change confirmation after 48 hours.
-
Cultural Medium Color Indication:
- Green to yellow color change for unsuccessful sterilization; purple for successful sterilization.
-
Dual D-Value Information:
- Provides D-values for 121 ºC, and informed values at 132ºC and 135ºC.
-
Fluorescence Detection Capability:
- Alternative rapid assessment of sterilization effectiveness.
-
Humidity Consideration for 7-Day Readout:
- Requires humidified environment to prevent medium drying out.
-
Shelf Life:
- 2-year expiration date under recommended storage conditions.
-
User-Friendly Instructions:
- Includes clear usage instructions, labeling, packaging guidelines, and post-sterilization procedures.
Purchase separately:
Rapid, Super Rapid or Ultra Rapid biological indicators
Autoclave LogBook for Steam Sterilizers
MINIBIO Auto-Reader Incubator
Ultra Rapid Self-Contained Biological Indicator
- 50 Biological Indicators per box
Storage Guidelines
- Store in a dark place within the temperature range of 10-30 °C and 30-80% relative humidity.
- Avoid freezing and keep biological indicators away from sterilizing agents or other chemical products.
Instructions for Use: Bionova Ultra Rapid Biological Indicators
Labeling SCBI:
- Identify SCBI with sterilizer number, load number, and processing date.
Packaging and Placement:
- Pack SCBI with materials for sterilization, placing it in less exposed areas.
Sterilization Process:
- Carry out standard sterilization procedures.
Post-Sterilization Steps:
- After sterilization, open the door, wait five minutes, and carefully remove SCBI.
- Caution: Wear safety glasses and gloves.
- Warning: Avoid excessive handling to prevent glass ampoule bursting. Let SCBI cool to room temperature.
Process Indicator Check:
- Inspect the Process Indicator on SCBI label. Brown color indicates exposure to steam.
- Note: Color change does not confirm sterility; further checks are needed if no change.
Ampoule Crushing and Incubation:
- Seal the tube's lid and crush the ampoule using an ampoule crusher.
- Shake the tube to soak the spore carrier completely.
- Place SCBI in the incubator.
- Important: Use a non-sterilized SCBI as a positive control daily. Ensure both controls are from the same batch.
Incubation and Readout:
- Incubate processed and positive control indicators for a maximum of 20 minutes at (60 ± 2) °C.
- Note: Incubation should not exceed a 7-day period after sterilization.
- Failure in sterilization is indicated by fluorescence detection.
- Negative result if no fluorescence at 20 minutes.
- Positive control must show positive fluorescence readout.
- Record positive results and discard SCBI promptly as instructed.
- WARNING: Do not use SCBI to control sterilization processes other than those specified.
- WARNING: Place one or more SCBI in hard-to-reach areas to ensure complete chamber sterilization. Evaluate load configurations to identify and place SCBI in all such locations.
- WARNING: Do not reuse SCBI.
- WARNING: Do not reuse the sterilizer until the SCBI test result is negative.
Q: How should I clean the external surfaces of the MiniBio Auto-reader?
A: Disconnect power and USB cables, wait for cooling. Use a damp microfiber cloth with mild detergent solution. Wipe, then rinse with water. Air dry for at least 1 hour before reconnecting cables.
Q: When should I perform the cleaning procedure?
A: Clean externally whenever spills occur or as considered appropriate. It's crucial after any spill on the device.
Q: Can I clean the internal parts of the Auto-reader?
A: No, do not clean internal parts. Contact your local distributor if further cleaning is needed or if unsure about cleaning agents.
Q: What if additional cleaning is required or I'm uncertain about cleaning agents?
A: Contact your local distributor for guidance.
Maintenance and Warranty
Q: Does the MiniBio Auto-reader require routine maintenance?
A: No, routine maintenance is not required. **
Q: What does the warranty cover, and for how long?
A: Terragene guarantees material and manufacturing quality. Warranty is 1 year from the date of first use, not extending beyond 5 years from manufacture.
Q: What is the procedure if a material or manufacturing fault is detected during the warranty period?
A: Terragene will repair or replace the product if material or manufacturing faults are detected within the warranty period.
Q: What is Terragene®'s liability in case of loss or damage resulting from equipment use?
A: Duraline Systems Inc. and Terragene are nnot liable for loss or damage due to unsuitable use, negligence, or user's full responsibility.
Technical Assistance
Q: How can I contact Duraline Systems for technical assistance?
A: Yes
Maintenance and Warranty Q: Does the MiniBio Auto-reader require routine maintenance? A: No, routine maintenance is not required.
** Q: What does the warranty cover, and for how long? A: Terragene guarantees material and manufacturing quality.
Warranty is 1 year from the date of first use, not extending beyond 5 years from manufacture.
Q: What is the procedure if a material or manufacturing fault is detected during the warranty period? A: Terragene will repair or replace the product if material or manufacturing faults are detected within the warranty period.
Discover more in our FAQ
Shoot our team an email & we’ll get back to you ASAP
How do I look up disinfectant on List N?
How do I look up disinfectant on List N?
First, find the product registration number. This can be found on the product label or safety data sheet. Duraline posts most registrations in the Product Description field of the product page in our website. Second, go to the epa.gov website: https://cfpub.epa.gov/giwiz/disinfectants/index.c... and enter the first 2 parts of the registration number and click enter.
My product has 3 parts on the registration number and I can't find all 3 on the approved website for List N. Why?
My product has 3 parts on the registration number and I can't find all 3 on the approved website for List N. Why?
The first 2 parts of the EPA Registration Number are the primary numbers and represent the primary registration. Since different companies sell products with the same chemical composition and efficiency, only 1 brand or product name receives the primary number. The third part represents the distributor of the primary registration and is still on List N and is proven effective against SARS-CoV-2 (COVID-19).
I can't find Swovo disinfectant wipes on List N. Where is it?
I can't find Swovo disinfectant wipes on List N. Where is it?
The EPA Registration number for Swovo is 59894-10-98425
To find this on the epa.gov website, you only need to enter the first 2 parts of this number, "59894-10"
This primary registration number is on the list, and so it is approved! See screenshot below.