Refurbished Midmark Ritter M9D Ultraclave, Gen 1
IMPORTANT: The M9D has a manual door, requiring the user to open it before the drying cycle.
Sterilization is made easy with the Midmark Ritter M9 Autoclave. Simply press the Start/Standby button and this autoclave will fill itself with the appropriate amount of water automatically. Once the autoclave is filled with water, select your cycle and the M9 will set the time for you. Cycle time from start to finish is 22 minutes (if cold) and 12 minutes (if hot).
Features:
IMPORTANT: The M9D has a manual door, requiring the user to open it before the drying cycle.
If you are looking for a fully automatic M9, please see below:
Automatic
Sterilization is made easy with the Midmark Ritter M9 Autoclave. Simply press the Start/Standby button and this autoclave will fill itself with the appropriate amount of water automatically. Once the autoclave is filled with water, select your cycle and the M9 will set the time for you. Cycle time from start to finish is 22 minutes (if cold) and 12 minutes (if hot).
Features:
- Low water indicator light tells you when the reservoir level is too low
- A door-ajar light tells you if the door is not securely closed
- LED display shows the units temperature during heat-up and time remaining during cycles.
- Lights turn on progressively during filling, heating, sterilizing, drying and complete stages.
- Easy to fill and to drain water - located at the front of the machine
- A large capacity water reservoir means you fill it less often!
- Four stainless steel trays come with the unit (two large, two small)
- Easy-to-read pressure gauge and electronic controls offer simple operation and reduce down time
Warranty: 30-Day parts and labor - ONLY
- Chamber Size: 9" x 15"
- Volume: 3.5 gal (13.4 L)
- Dimensions (L x W x H): 20.4" x 15.3" x 15.38"
- Trays: 4
- Tray Size (L x W x H): Two Large: 7.3" W x 12" L x 0.8" D & Two Small: 5.6" W x 12" L x 0.8" D
- Standard Unwrapped Cycle Time: Cold: 30 Min & Hot: 14 min
- Voltage: 115V
- Frequency: 50/60
- Current: 15A
- Shipping Weight: 81 lbs
- Minimum Countertop Area: 15.3" W x 17.9" D
- Manual Door
| Sterilization Programs | Temp. | Hot Cycle Time (fill, heat-up & vent) | Sterilization Time | Dry Time | Total Hot Cycle Time (without dry) |
Total Hot Cycle Time (with dry) | |
| Description | Icon | ||||||
| Unwrapped |
|
270° F | 11 min | 3 min | 30 min | 14 min | 44 min |
| Pouches |
![]() |
270° F | 12 min | 5 min | 30 min | 17 min | 47 min |
| Packs |
![]() |
250° F | 10 min | 30 min | 30 min | 40 min | 70 min |
| Handpieces |
![]() |
270° F | 11 min | 6 min | 30 min | 17 min | 47 min |
Midmark / Ritter M9D Ultraclave Old Style Brochure
Midmark / Ritter M9D Ultraclave, Old Style Operators Manual
Approvals:
Midmark / Ritter M9D Ultraclave, Old Style Operators Manual
Approvals:
- Meets the requirements of ASME Boiler and Pressure Vessel Code
- UL Listed to U.S. & Canadian Standards
Q. What is the difference between MY9D and M9 Midmark Ritter autoclave?
A. The M9 door pops afar to automatically begin the dry cycle. The M9D requires you to be by the autoclave and needs to manually be opened to begin the dry cycle.
A. The M9 door pops afar to automatically begin the dry cycle. The M9D requires you to be by the autoclave and needs to manually be opened to begin the dry cycle.
it less often! Four stainless steel trays come with the unit (two large, two small) Easy-to-read pressure gauge and electronic controls offer simple operation and reduce down time Warranty: 30-Day parts and labor - ONLY