Refurbished Market Forge Sterilmatic STM-E Steam Sterilizer
Regular price
$7,468.00
Sale price
Shipping calculated at checkout.
Couldn't load pickup availability
Market Forge STM-E Analog Sterilmatic Steam Autoclave Sterilizer Refurbished
WARRANTY: 6 months parts only
WARRANTY: 6 months parts only
The Largest Capacity in the most compact space! Small on the outside, the Sterilmatics has as much inside capacity as many large, more costly conventional sterilizers and up to five times the capacity of smaller table top units.
Economical, reliable and simple to operate, the versatile Sterilmatics provides the highest standards of sterilizing performance in a number of facilities, such as, Laboratories, Veterinary Clinics, Food Processing Plants, Wineries, Fisheries, Dairy Processing Plants, and more.
Sterilize glass beakers, pipettes, test tubes and flasks. Metal and plastic instruments, syringes, needles, brushes, rubber gloves, catheters, rubber tubing, dressings, linens, petri dishes and more.
Standard Features:
- Automatic temperature controls
- Temperature up to 250°F (121°C)
- Thermostatic steam trap
- Thermometer range 180°-300°F (82°-149°C)
- 0-30 lb. steam gauge
- 0-60 minute timer
- Low water cut-off, signal light, and safety valve
- Flat perforated steam baffle
- Removable pan supports
- 18-3/4” wide x 27-5/8” high x 31” deep (55-1/4” high on optional stand)
Warranty: 6 months parts only
View Market Forge Options and Accessories
View Market Forge Options and Accessories
- Controls: Manual
- Chamber: 16" x 26"
- Cylinder: 3/16" (4.8mm) thick welded aluminum, which ensures durability and strength.
- Sterilizer exterior: Polished stainless steel.
- Stainless steel is commonly used in medical and laboratory settings because it is resistant to corrosion and easy to clean.
- Dimensions (L x W x H): 31" x 18.75" x 27.6"
- Interior dimensions: Diameter of 16" (406mm) and a length of 26" (660mm)
- cubic content of the cylinder is 5,220 cubic inches (85 liters)
- Door opening of 13-1/2” (343mm) wide and 11” (279mm) high.
- Voltage: 208, or 240 Volts, 60Hz, 1 or 3 phase
- 18-3/4” wide x 27-5/8” high x 31” deep (55-1/4” high on optional stand)
- Sterilizing compartment will have a pan capacity of: Accessories
- (3) 12” x 20” x 2-1/2” (305mm x 508mm x 64mm) or
- (2) 12” x 20” x 4” (305mm x 508mm x 102mm) or
- (1) 12” x 20” x 6” (305mm x 508mm x 152mm)
- Additional information: Detailed specifications
Q. Can I use distilled water in Market Forge Sterilematic sterilizers?
A. No, distilled water is NOT recommended by the manufacturer. See Installation Page 2 of the operators manual
WATER CONDITIONS
When sterilizing culture mediums that generate sulfide gas or chlorine gas, the inside of the chamber must be cleaned and rinsed thoroughly without fail. Market Forge from time to time is asked the question about using distilled or deionized water for use with our Sterilizer models STM-E and STM-EL. We are always asked why these water choices are not allowed for use with our units and what would be recommended. To address this situation, we have complied the following as a means of satisfying these questions:
1. We have found that the use of distilled or deionized water will aggressively attack the pure coat of Aluminum Alclad, which protects the bottom surface from oxidizing and then eventually pitting (reference: Operating and Maintenance Instructions).
2. In addition pitting can also be caused by several other external environmental factors. Few examples are as follows. These conditions have been highlighted in our documentation.
• Grains of hardness in the water supply should be as follows (.25 to 2).
• A pH imbalance in the water supply can greatly affect the life to the aluminum cylinder. The pH range that would be recommended is between 7.0-8.5.
• The lack of a positive electrical ground can cause an electrolytic reaction that will accelerate pitting.
• Another contribution to accelerate pitting is the type of cleaning solutions used or the abrasive scrubbing pads. If a low pH is present with the detergents being used or an abrasive pad, the protective Alclad coating will be removed during the cleaning process.
• Spillage of media being sterilized can also contribute to the accelerated pitting if it is corrosive.
• CHLORINE LEVEL ≤ 1 PPM.
A. No, distilled water is NOT recommended by the manufacturer. See Installation Page 2 of the operators manual
WATER CONDITIONS
When sterilizing culture mediums that generate sulfide gas or chlorine gas, the inside of the chamber must be cleaned and rinsed thoroughly without fail. Market Forge from time to time is asked the question about using distilled or deionized water for use with our Sterilizer models STM-E and STM-EL. We are always asked why these water choices are not allowed for use with our units and what would be recommended. To address this situation, we have complied the following as a means of satisfying these questions:
1. We have found that the use of distilled or deionized water will aggressively attack the pure coat of Aluminum Alclad, which protects the bottom surface from oxidizing and then eventually pitting (reference: Operating and Maintenance Instructions).
2. In addition pitting can also be caused by several other external environmental factors. Few examples are as follows. These conditions have been highlighted in our documentation.
• Grains of hardness in the water supply should be as follows (.25 to 2).
• A pH imbalance in the water supply can greatly affect the life to the aluminum cylinder. The pH range that would be recommended is between 7.0-8.5.
• The lack of a positive electrical ground can cause an electrolytic reaction that will accelerate pitting.
• Another contribution to accelerate pitting is the type of cleaning solutions used or the abrasive scrubbing pads. If a low pH is present with the detergents being used or an abrasive pad, the protective Alclad coating will be removed during the cleaning process.
• Spillage of media being sterilized can also contribute to the accelerated pitting if it is corrosive.
• CHLORINE LEVEL ≤ 1 PPM.
Market Forge STM-E Analog Sterilmatic Steam Autoclave Sterilizer Refurbished WARRANTY: 6 months parts only
| Product Code | Description | OEM | View | |
| MF1018A-AM |
12' x 20' x 2' Perforated Tray (Unit will holds three of this size) |
Replaces 10-1203 | Add To Cart | |
| MF1018B-AM |
12" x 20" x 4" Perforated Tray (Unit will hold (2) of these, as well as (1) 2-1/2" tray) |
Replaces 10-1204 | Add To Cart | |
| MF1018C-AM |
12" x 20" x 6" Perforated Tray (Unit holds (1) of these, as well as (1) 2-1/2" tray) |
Replaces 10-1205 | Add To Cart | |
| MF1018D | 12" x 20" x 2-1/2" Wire Basket | 10-1228 | Add To Cart | |
| MF1018E | 12" x 20" x 4" - Wire Basket | 10-1229 | Add To Cart | |
| MF1076 |
Exhaust Condenser (can't be connected to outside vent) |
95-0436 | Add To Cart | |
| MF1077 | Exhaust Condenser 240V, 50/60 Hz | 95-3629 | Add To Cart | |
| MF1021 |
Spare Parts Kit (STM-E & STM-EL Models) |
95-6061 | Add To Cart | |
| MF1022 |
Spare Parts Kit (STM-EX & STM-ELX Models) |
95-6062 | Add To Cart | |
| MF1000 |
New Chamber Cylinder Kit Buy refurbished with NEW chamber! |
98-4217 | Add To Cart | |
| MF1016 | Recording Thermometer 120V / 60 Hz | 95-6233 | Add To Cart | |
| MF1023 | Recording Thermometer 230V / 50Hz | 95-6234 | Add To Cart | |
| MFSTAND | Stand 28" high. Includes 1 shelf. | 95-6060 | Add To Cart | |
| MF1014 | Extra Shelf (for stand MFSTAND) | 95-6054 | Add To Cart |