Refurbished Tuttnauer 2340EK Autoclave
Couldn't load pickup availability
NOTE: The 2340EK requires a 230V electrical circuit.
Features:
- Pre-loaded cycles for: unwrapped instruments, wrapped/packs; liquid and additional drying cycle
- All program parameters can be changed and stored
- Automatic shut off at the end of both the sterilization and dry cycles
- Audible and visual cycle interruption alert
- Double safety locking device prevents door from opening while chamber is pressurized.
- Low water sensor prevents activation of sterilization cycle when there is insufficient water in the chamber or reservoir
- Constant monitoring of temperature and pressure for sterilization
- Power outage recovery system
- Door design prevents steam from coming in contact with control panel
- The 2340EKA requires a 230V electrical circuit
- WARRANTY: 30 day, 3- & 6-months parts and labor
- 30 Day parts and labor
-
3 months parts and labor
- 6 months parts and labor
- Chamber Size: 9" x 18"
- Chamber Volume: 5 Gal - 19 Liters
- Overall Dimensions: 21.5" D x 20" W x 14.4" H
- Standard Cassettes Capacity: 2 full and 2 half
- Tray Dimensions: 16.3" x 6.7" x 0.8"
- No. of Trays: 3
- Standard Unwrapped Cycle Time: Cold: 14 Min. Hot: 11 Min.
- Voltage (V) - Frequency (Hz) 230 - 50/60
- Power (W) - Current (A) 2200W - 9.6A
- Autoclave Weight - Lbs (kg) 73 (33)
| Sterilization Programs | Temp. | Sterilization Time | Dry Time | |
| Description | Icon | |||
| Unwrapped Instruments & materials | 273° F | 3 min | 0 | |
| Wrapped Instruments & porous load | ![]() | 273° F | 7 min | 60 min |
| Glassware | 250° F | 30 min | slow exhaust: 15-20 min | |
| Drying (continues the heat assisted drying process) | ![]() | accessory | for extra drying | if needed |
|
Tuttnauer 2340EK Operators Manual
Tuttnauer 2340EK Brochure
Tuttnauer autoclaves are FDA cleared and comply with the following Standards:
Technical Standards
1. A.S.M.E. Code, Section VIII div.1 for unfired pressure vessels.
2. AAMI/ANSI ST-55:2001 Tabletop steam sterilizers.
3. UL61010-1 Safety for Electrical Equipment for Measurement, Control, and Laboratory Use, General Requirements.
4. UL61010-2-041 Particular Safety for Autoclaves.
Quality Standards
The manufacturing plant meets the following quality standards:
1. EN ISO 9001:2000:2008– Quality System.
2. ISO 13485:2003 – Quality systems – Medical devices – Particular requirements for the application of ISO 9001
|
Discover more in our FAQ
Shoot our team an email & we’ll get back to you ASAP
How do I look up disinfectant on List N?
How do I look up disinfectant on List N?
First, find the product registration number. This can be found on the product label or safety data sheet. Duraline posts most registrations in the Product Description field of the product page in our website. Second, go to the epa.gov website: https://cfpub.epa.gov/giwiz/disinfectants/index.c... and enter the first 2 parts of the registration number and click enter.
My product has 3 parts on the registration number and I can't find all 3 on the approved website for List N. Why?
My product has 3 parts on the registration number and I can't find all 3 on the approved website for List N. Why?
The first 2 parts of the EPA Registration Number are the primary numbers and represent the primary registration. Since different companies sell products with the same chemical composition and efficiency, only 1 brand or product name receives the primary number. The third part represents the distributor of the primary registration and is still on List N and is proven effective against SARS-CoV-2 (COVID-19).
I can't find Swovo disinfectant wipes on List N. Where is it?
I can't find Swovo disinfectant wipes on List N. Where is it?
The EPA Registration number for Swovo is 59894-10-98425
To find this on the epa.gov website, you only need to enter the first 2 parts of this number, "59894-10"
This primary registration number is on the list, and so it is approved! See screenshot below.