New Scican Statim G4 5000 Cassette Autoclave
Couldn't load pickup availability
New Scican Statim 5000 G4 Cassette Sterilizer
IMPORTANT: WE CAN ONLY SHIP WITHIN OUR SERVICE AREA NEW YORK, NEW JERSEY & CONNECTICUT.
FAST.
- Monitoring real-time cycle data
- Instant data logging
- Proactive maintenance management
- Automatic system updates to your G4 machines
Features:
- Immediate Steam Generation - Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a ‘steam generator’, rapidly heated and converted to steam in mere seconds.
- Air Removal - Using PPPD technology and our patented steam injection process – air is automatically forced out of the sterilization chamber
- Cassette System - The thin stainless steel walls of STATIM™s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave
- Drying Technology - The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying
- Touch - A large 3.5†high-resolution touchscreen offers a vivid display of messages, current cycle information and customizable colours all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-centre
- Connect - Through your networked portal, you can view not only your STATIMs current operations in real time, you can also access cycle history, printing and validation information, and also sterilization records. Capable of sending emails with cycle information errors directly to your dealer, your STATIM G4 will let qualified technicians know when service is imminent
- Protect - Patient safety relies on attention to detail. The STATIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle. This encourages extra attention to process and creates a safer environment for both staff and patients
- Collect - An undocumented sterilization cycle might as well not have been performed. With each cycle, information must be stored to protect your office and your patient. The integrated DataLogger stores all cycle information for the lifetime of the unit, which is accessible through multiple channels such as: a USB port for manual retrieval; an Ethernet connection for web based archiving or desktop printing; or a RS232 port for an external printer option.
- Immediate Steam Generation - Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a ‘steam generator’, rapidly heated and converted to steam in mere seconds.
- Air Removal - Using PPPD technology and our patented steam injection process – air is automatically forced out of the sterilization chamber
- Cassette System - The thin stainless steel walls of STATIM’s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave
- Drying Technology - The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying
- Touch - A large 3.5†high-resolution touchscreen offers a vivid display of messages, current cycle information and customizable colours all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-centre
- Connect - Through your networked portal, you can view not only your STATIMs current operations in real time, you can also access cycle history, printing and validation information, and also sterilization records. Capable of sending emails with cycle information errors directly to your dealer, your STATIM G4 will let qualified technicians know when service is imminent
- Protect - Patient safety relies on attention to detail. The STATIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle. This encourages extra attention to process and creates a safer environment for both staff and patients
- Collect - An undocumented sterilization cycle might as well not have been performed. With each cycle, information must be stored to protect your office and your patient. The integrated DataLogger stores all cycle information for the lifetime of the unit, which is accessible through multiple channels such as: a USB port for manual retrieval; an Ethernet connection for web based archiving or desktop printing; or a RS232 port for an external printer option.
STATIM G4 Warranty Update (Effective January 2026)
- Controls: Automatic
- Dimensions (L x W x H): 23.6” x 16.1” x 7.5”
- Cassette internal dimensions: 15” x 7” x 3”
- Cassettes: 1
- Voltage: 115V, 50/60 Hz, 15A / 1450 W
- Weight without water: 73 lbs (33 kg)
| Description | Sterilization Temperature | Sterilization Time | Total Cycle Time |
| Unwrapped Instruments | 270° F | 3.5 min | 9 min |
| Wrapped Instruments | 270° F | 6 min | 17.5 min |
| Rubber, plastic | 250° F | 35 min | 45 min |
| Heavy Duty Unwrapped / Air Drying | 270° F | 6 min | 12 min |
WARRANTY: 12 months parts and labor STATIM G4 Warranty Update (Effective January 2026) Sterilizers manufactured January 2026 and later (Serial range: XXXX26AXXXX) include a 2-year manufacturer warranty when the unit is connected and registered on myCOLTENE.
Units that are not connected and registered default to a 1-year warranty.
Registration should be completed at installation to ensure full warranty eligibility and proper service tracking.