Refurbished Steris Century V160 Steam Sterilizer

WARRANTY: 1 year parts and labor, 6 months on PM Parts, 5 warranty years on pressure vessel

Steris V160 Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The V160 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 60″ chamber, the V160 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind.

Features:
  • Florescent display for easy reading
  • Ink on paper impact printer
  • 26″ x 37.5″ x 60″ chamber
  • Pre-vacuum Steam Sterilizer
  • Fast & efficient
  • Emergency manual exhaust valve
  • Non-lubricated, steam-activated door seal
  • Help screens for programming/troubleshooting alarm conditions
  • Communication interface compatibility w/ most PC devices
  • Electronic water conservation valve
  • Optional Stainless steel side panels available.

1 Year Parts & Labor Warranty, 6 months on PM Parts, 5 warranty years on pressure vessel. Standard Preventative Maintenance must be completed while unit is under warranty.

Additional Options: Cabinet Package, Loading Cart, Integral Steam Generator, Water Filtration Options

Steris Amsco Century V160 Medium Steam Sterilizer Options:

Chamber Size Doors Door Configurations Mounting Steam Source Vacuum Pump Electric Service Accessories
26" x 37.5" x 36"
(660 x 950 x 910 mm)
Single Hinged
or
Horizontal Sliding
Cabinet Enclosed (Freestanding)
or
Recessed
Building Steam 208/240 VAC, 60 Hz, 3-Phase, 6A per phase
or
480 VAC, 60 Hz, 3-Phase, 3A per phase
Loading Car, Transfer Carriage, and Track Assembly
Chamber Rack and Shelf
Seismic Tie-Down Kit
26" x 37.5" x 48"
(660 x 950 x 1220 mm)
Single Hinged
or
Horizontal Sliding
Cabinet Enclosed (Freestanding)
or
Recessed
Building Steam 208/240 VAC, 60 Hz, 3-Phase, 6A per phase
or
480 VAC, 60 Hz, 3-Phase, 3A per phase
Loading Car, Transfer Carriage, and Track Assembly
Seismic Tie-Down Kit
Double Hinged
or
Horizontal Sliding
Recessed through One Wall
or Two Walls
Building Steam 208/240 VAC, 60 Hz, 3-Phase, 6A per phase
or
480 VAC, 60 Hz, 3-Phase, 3A per phase
Loading Car, Transfer Carriage, and Track Assembly
Seismic Tie-Down Kit
26" x 37.5" x 60"
(660 x 950 x 1520 mm)
Single Hinged
or
Horizontal Sliding
Cabinet Enclosed (Freestanding)
or
Recessed
Building Steam 208/240 VAC, 60 Hz, 3-Phase, 6A per phase
or
480 VAC, 60 Hz, 3-Phase, 3A per phase
Loading Car, Transfer Carriage, Chamber Track Assembly
Seismic Tie-Down Kit
Double Hinged
or
Horizontal Sliding
Recessed through One Wall
or Two Walls
Building Steam 208/240 VAC, 60 Hz, 3-Phase, 6A per phase
or
480 VAC, 60 Hz, 3-Phase, 3A per phase
Loading Car, Transfer Carriage, Chamber Track Assembly
Seismic Tie-Down Kit

All processing cycles factory programmed into the sterilizer control have been validated to AAMI ST8.
Prevacuum configuration sterilizers are factory programmed with the following cycles:

270°F (132°C) Prevacuum (with either
5-minute or 20-minute dry phases) - For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) - Sterilize time: 4 minutes - Dry time: 5 minutes or 20 minutes

Gravity, Liquid, 250°F (121°C) - For sterilizing fabrics, Sterilize temperature: 250°F (121°C) - Sterilize time: 30 minutes - Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)

270°F (132°) Gravity Cycle: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) - Sterilize time: 15 minutes - Dry time: 30 minutes (Note: 270°F temperature must be set by the user)

SFPP configuration sterilizers are factory programmed with the
following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.
Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.
Sterilize temperature: 270°F (132°C) - Sterilize time: 4 minutes - Dry time: 20 minutes

WRAP/SFPP Cycle: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. - Sterilize temperature: 270°F (132°C) - Sterilize time: 4 minutes - Dry time: 20 minutes

Liquid Cycle: This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) - Factory programmed sterilize time: 45 minutes - Dry time: not applicable

275°F (135°C) Prevacuum Cycle: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes


Utility Requirements

Steam
• 1” NPT
• 50 to 80 psig (3.5 – 5.6 bar) dynamic
• 97% - 100% vapor quality
Drain
• 2” ODT drain terminal
Electrical - Controls
• 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp

Electrical–Vacuum Pump

208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.
480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.

Sterilizer Feed Water
1" NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.

Frequently Asked Questions

Shoot our team an email & we’ll get back to you ASAP

How do I look up disinfectant on List N?

First, find the product registration number. This can be found on the product label or safety data sheet. Duraline posts most registrations in the Product Description field of the product page in our website. Second, go to the epa.gov website: https://cfpub.epa.gov/giwiz/disinfectants/index.c... and enter the first 2 parts of the registration number and click enter.