Priorclave Dual 150L Front Loading Chambers Electrically Heated Autoclave
Priorclave autoclaves offer an unparalleled 36-month parts and labor warranty, and a 20-year pressure vessel warranty.
The ideal solution for the autoclaving needs of many laboratories, the Priorclave EH150 Stackable laboratory autoclave is well suited for use in a wide range of applications:
Sterilization: media preparation, liquids and diluents, waste, glassware, instruments, apparatus Non-Sterilization: food processing, quality control, plastics, accelerated curing, destruction testing
The EH150 Stackable laboratory autoclave is extensively used within many industries, including education, life sciences, pharmaceutical, agricultural, industrial, food and drink, dairy, and brewing. Features:
- Operating Range: Up to 136°C, 2.4 Bar (277°F, 34.8psi)
- Working Dimensions: 496mm (19.5”) diameter x 740mm (29.1”) deep (upper and lower chambers)
- Chamber Material: Brushed grade 316L stainless steel
- Door Material: Burnished grade 316L stainless steel
Priorclave sterilizers are built in the UK to a modular design enabling easy upgrading during their working life as your requirements change. Every steam heated Priorclave is fitted with a Thermostatic Air Purge Valve and an electrically operated Vent Valve. All pipe to pipe joints are brazed with compression joints to specific components (stainless pipework is available). Priorclave autoclaves offer a 36-month limited parts and labor warranty, 20-year pressure vessel warranty, and unlimited technical support.
Safety
All Priorclave autoclaves comply with current US, Canada, UK, and EU safety regulations, and are manufactured under an ISO 9001:2008 quality management system. All pressure vessels are manufactured in-house and tested to 1.5 times their maximum working pressure. They have full Insurance approval for pressure vessel design and construction and are CE Marked under the Pressure Equipment Directive PD5500:2000 Cat 3, Certificate Number SS42059010-2 Rev 1. They also conform to the general requirements of BS2646 and are CE Marked for BS EN61010-2-41, Low Voltage and Electromagnetic Compatibility.
At Priorclave, the safety of your staff and students, comes first. Priorclave is the only manufacturer offering the sophisticated Tactrol® 2 Control System on every model – benchtop to double-ender. Program cycles are simple push-button and/or keyswitch activated. Program modifications are keyswitch and/or password protected, and interface directly with your PC. The Tactrol 2 controller has the unique ability to be as simple as it needs to be, or as sophisticated as your process demands. Everything is within your control, and no additional training is required when moving from one unit to another. The Quickseal 2 door, with Permission-based Door Release, is fitted with thermal and pressure locks preventing opening of the autoclave at load temperatures above 80°C (176°F) and pressures above 0.2 Bar (2.9 psi) (BS2646).
The door is also fitted with a Redundant Safety Gate, allowing potential residual pressure to safely escape before the door can be fully opened (in accordance with the UK Health and Safety Executive’s note PM73). Fitted with a Pressure Safety Valve set to 2.5 Bar (36.3 psi) and a 150°C (302°F) thermal cut out (BS6759); selected external panels and surfaces are Thermally Insulated. All front loading models are fitted with non-tip shelves.
EH150 Stackable Standard Features: 320L Front Loading Standard Features:
- Dual Chamber Design (upper and lower chambers
- Quickseal 2 Single Action Lid Closure System
- Permission-based Lid Release
- Thermostatic Air Purge Valve
- Low Water Cut Out (on models with in-chamber steam generation)
- Electrically Operated Vent Valve
- Fully Programmable Tactrol® 2 Control System
- Automatic Timed Freesteaming
- Assisted Load Cooling
- Media Warming and Delayed Start
- Chamber Pressure Gauge
- Thermocouple Entry and Test Ports
- 316L Stainless Steel Chamber and Door
- Two Stainless Steel Loading Baskets
- Caster mounted for ease of positioning and service
- Biomaster Antimicrobial Surfaces
- Reliable water and energy savings
Options:
- Tactrol 5 Program Memory
- Tactrol 10 Program Memory
- Upgrade Tactrol 5 to Tactrol 10 Program Memory
- Tactrol Self-Monitoring System
- Tactrol Plain-Paper Printer
- Setting Lock Key Switch (standard with any Tactrol memory unit)
- Pulsed Free Steaming
- Load Sensed Process Timing
- Automatic Water Fill System (models with in-chamber steam generation only)
- Water Softener
- Purified Water Level Sensor (models with in-chamber steam generation only)
- Stainless Steel Pipework
- Clean Steam Generation
- Air Intake Filter System
- Exhaust Filtration System
- Air Ballast System for Accelerated Liquid Cooling (with or without external air supply)
- Load Temperature Monitor
- Chamber Pressure Monitor
- Armored Wandering Probe
- External USB Port (included in North American models)
- Combined Pre-Cycle Vacuum & Vacuum Cooling
- Post-Cycle Vacuum Drying
- Automatic Cycle Repeat
- Stainless Steel Loading Basket
- Stainless Steel Waste Container
- Loading Hoist
- Drain Condenser
- Two-Year Spares Kit
- Three-Year Spares Kit
- IQ/OQ/PQ Documentation
Read More about Priorclave here
- Working Volume: (2) 150 Liters (39.63 gal)
- Operating Range: Up to 136°C, 2.2 Bar (277°F, 32 psi)
- Loading Format: Front Loading
- Loading Height: Lower: 12″ or 305mm / Upper: 48.4″ or 1229mm
- Heating: Electrical
- Heat Input: 10.5kW Three Phase
- Working Dimensions: 19.5” x 29.1” / 496mm x 740mm
- Bottom Shelf-Dimensions: 14.8”W x 29.1”D with 15.8” clearance (each chamber – upper shelf removed)
- Top Shelf Dimenstions: 19.1”W x 29.1”D with 9.5” clearance
- Outside Dimensions: 36.9” x 53.3” x 78.8”, 937mm x 1354mm x 2002mm
- Floor Weight (unloaded): 992.1 lbs (450Kg)
- Minimum Installation (w x d x h - and door swing): 1547mm x 2284mm x 2306mm 60.9” x 98.9” x 90.8” (625mm, 24.6” – both chambers)
Prioclave Dual 150L Front Loading Chambers Electronically Heated Autoclave Product Sheet
All Priorclave autoclaves comply with current US, Canada, UK, and EU safety regulations. They are manufactured under an ISO 9001:2008 quality management system in our UKAS-accredited facility. Our autoclaves and control systems are ETL listed and EMC certified, and feature ASME-stamped pressure vessels . These pressure vessels are manufactured entirely in-house, and tested to 1.5 times their maximum working pressure. They have full insurance approval for pressure vessel design and construction and are CE Marked under the Pressure Equipment Directive PD5500:2000 Cat 3, Certificate Number SS42059010-2 Rev 1. They also conform to the general requirements of BS 2646 and are CE Marked for BS EN61010-2-41, Low Voltage and Electromagnetic Compatibility.
|
|
|