Home > Instrument Cleaning > Washers Disinfectors >

Instrument Washer Disinfector Steelco DS 610 SL


Steelco DS 610 SL Instrument Washer Disinfector
 
 


Options:  Fast Cycle


Free Shipping
Product Code: DS610SL
Request Quote


Description Technical Specs Literature
 
Steelco DS 610 SL Washer Disinfector with filtered hor air drying system.

10 DIN 1/1 tray capacity, fully automatic washer disinfector with vertical sliding doors. Ideal solution for small CSSDs, can be equipped with automatic loading conveyors.

Steelco-DS610SL-sliding-doorFast Cycle configuration available.

The sliding down door of this device, allows a reduced machine encumbrance and is ideal in every reprocessing area, also when the space is very limited. The full HST glass motorized door provides the end user with a complete visual inspection during washing cycle.

This model is equipped with filtered forced hot air drying system.

The large capacity of this model (up to 10 DIN 1/1 net trays) assures consistently tested and efficient washing-disinfecting performances and can meet at the same time high reprocessing needs of a TSSU/CSSD solution.

Features
  • High safety and easy to use soft touch control system on glass panel with LCD colour display to visualize cycle status.
  • 20 standard pre-programmed cycles available and 20 additional cycles available for customization.
  • RS 232 port for printer connection to monitor/validate the washing phases.
  • Ergonomic design of the door level height allows convenient loading and unloading operations.
  • Washing and DI disinfection temperature are fully adjustable up to 93°C. Temperature is monitored by two independent sensors.
  • Machine can be equipped with a steam condenser to prevent vapours from entering into the washing area (optional).
  • Heavy washing pump ensure high water flow rate combined with effective spray pressure.
  • Washing/drying injection system on the same circuit.
  • Inner cabinet, washing arms and tank filters entirely made of high quality AISI 316L stainless steel. Frame and body of machine made of AISI 304 stainless steel.
  • Triple water filtering system ensures to capture residue, preventing re-circulation of contaminated material.
  • Two standard automatic liquid dispensers provided with level control.
  • Large storage on the basement to allocate up to four 5 lt (1.32 Gal US) chemical containers.
Optional
  • 3rd and 4th Chemical dosing pump
  • HEPA H14 air filter
  • Conductivity sensor
  • Integrated printer ST2
  • Light inside chamber
  • Sump steam heating
  • Basket recognition system
  • USB port
  • Analogic sensor on washing circuit for pressure check (registered data)
  • 1S or 2S Fast Cycle versions
  • Ethernet connection
  • Steam condenser (total machine height 2390mm/94.09”)
  • Drain water heat exchanger (Fast Cycle version only)
  • Additional chemical dosing monitoring (flow meters)
Features
Q: What solutions or detergents do I need for my Steelco washer disinfector?

A: It is essential to consider the type of detergent and rinse solutions used for optimal performance of Steelco washers. Here is a brief explanation:

  1. Detergent or Enzymatic Solution (Neodisher Forte Detergent):
    • Purpose: Ensures deposits and proteins are removed from instruments.
    • Benefits:
      • Excellent material compatibility and universally applicable.
      • Reliably removes residues of dried and denatured blood.
      • Prevents redeposition of protein residues.
  2. Neutralizing Rinse Agent ( Neodisher N):
    • Purpose: Maintains proper pH levels to prevent carryover and degradation of instrument materials.
    • Benefits:
      • Neutralizes carried over alkali residues.
      • Removes lime residues or other acid-soluble residues during automated reprocessing.
  3. Rinse Aid ( Neodisher MediKlar):
    • Purpose: Ensures lubrication of instrument joints, prevents scale build-up, and promotes quick and complete drying.
    • Benefits:
      • Provides rapid, stain-free drying of surgical instruments, including ophthalmological instruments, anesthesia utensils, containers, and implants.
      • Significantly shortens drying time.

Recommendation: Always refer to the Instructions for Use (IFUs) and consider the specific items being processed. Chemicals can mitigate issues with poor water quality, but severe water quality problems must be addressed before using washers. Testing water quality is typically done before the construction and installation of equipment to meet the specifications required for surgery centers.


Accessories
Instrument Washer Disinfector Steelco DS 610 Steelco DS 50 HDRS Instrument Washer Disinfector Neodisher N Liquid Concentrate Neutralizing Rinse Agent, 5-liters Instrument Washer Disinfector Steelco DS 500 CDL

Add Free Shipping

Add Free Shipping
Price: $290.00

Add Free Shipping

Add Free Shipping
Steelco DS 610 Instrument Washer Disinfector Steelco DS 50 HDRS Washer Neodisher N Neutralizing Rinse Agent Instrument Washer Disinfector Steelco DS 500 CDL
Neodisher MediClean Forte Detergent, 5 Liters or 10 Liters Neodisher MediKlar Rinse Agent, 5 liters
Price: $407.00

Add Free Shipping
Price: $260.00

Add Free Shipping
Neodisher MediClean Forte Detergent Neodisher MediKlar Rinse Agent Steelco Instrument Washer Disinfector Detergent 404533

Share your knowledge of this product. Be the first to write a review »