Skip to content
To take full advantage of this site, please enable your browser's JavaScript feature.
Close Menu
Checkout
FREE SHIPPING ON ORDERS OVER $500
Helpful Links
Pay Invoice
Reorder
My Account
Contact Us
Search site:
Infection Control
Access Control
Hand-held Thermometer
Reusable Forehead Thermometer
Wall Mount Thermometers
Face Protection
Surgical Masks
N95 & N99
Respirators & PAPR
Respirator Filters & PAPR Accessories
Face Shields
Medical Goggles
Learning Lab: Respirators for Healthcare: N99, ELIPSE P100, PAPR
Hand Hygiene
Hand Sanitizer
Hand Soap
Hand Wipes
No Rinse Spray Handwash
Dispensers & Stands
Isolation Gowns
Exam Gloves
BioHazardous Waste
Surface Disinfectants
PPE Storage
UV Decontamination
CLEARANCE
Instrument Cleaning
Enzymatic Cleaners
Instrument Lubricants, Trays & Brushes
Cleaning Brushes
Lubricants
Strainers and Soaking Trays
High Level Disinfectant Sterilant
Ultrasonic Cleaning Equipment
DuraSonic
Ultrasonic Cleaners
BioSonic
Crest
H/T
H/T/PC
CP1200 Series
CP1800 Series
CP230 Series
CP2600
CP360
CP500
Baskets & Accessories
Germicidal Instrument Cleaner
Clean & Simple
Recessed Ultrasonic Cleaners
Washers Disinfectors
Washers Disinfectors Accessories
Rinse Agents & Detergents
Water Purification
Water Distillers
1 Gallon Water Distillers
Reverse Osmosis
Labeling & Storage
Instrument Trays
Stainless Steel Instrument Trays
Plastic Instrument Trays for Sterilization
Labelex Labels & Dispensers
Single-Ply Labels
Dual-Ply Labels
Ink Rollers
Label Dispensers
Instrument Pouches
Steam Autoclave Pouches
EtO Gas Instrument Pouches
Dry Heat Sterilizer Pouches
Sterilization Wraps
Indicator Tape
Sterilization Tubing & Sealers
Sterilization Centers
SteriLine Sterilization Centers
Cabinetry
Sterilizers
Steam Autoclaves
Automatic Tabletop Autoclaves
Tuttnauer T-Edge
Manual Tabletop Autoclaves
Cassette Autoclaves
Large Capacity Autoclaves
Class B Pre Post Vac
Class B Pre Post Vac 85L Tuttnauer 3870HSG Autoclave Brochure
Life Science Solutions
Research Sterilizers
Good Working Autoclaves
Autoclave Cleaner
RapidHeat Sterilizers
Plasma Sterilizers
Dry Heat Sterilizers
Ethylene Oxide (EtO)
Compare EO Gas Sterilizers
Anprolene AN75 Series
FDA Approved EO Gas Sterilizers
EOGas 4 Series
EOGas 3 Series
Emissions Abators
Accessories
Sterilizer Parts
Gaskets
Coils & Heater Elements
Switches & Timers
Power Circuit Boards & Electronic Components
Covers & Panels
Filters
Valves & Solenoids
Wires, Sensors & Connectors
Door Components
Drain Tubes & Waste Bottles
Parts and Accessories for the Enbio Class B Autoclave
Accessories
Autoclave Stand
Autoclave Racks
Pouch Racks
Statim Racks
Tray Racks
Sterilizer Trays
Cassettes
Cox 6000
Midmark Ritter
OEM
Pelton & Crane Trays
Replacement
SteriDent SteriSure
Tuttnauer
Sterilizer Printers, Ribbons, SteriData Loggers
Micro Sterilizers
New Sterilizers
Refurbished Sterilizers
Refurbished Autoclaves Sale
Learning Lab
5 Ways to Select the Right Laboratory Sterilizer
Autoclave Safety
Brand Spotlight: Tuttnauer
Did you know Preventative Maintenance is required by the CDC?
EO Gas Sterilizer FAQ's
How Do Autoclaves Work?
How to Care for Your Autoclave or Steam Sterilizer
How To Spore Test Your Autoclave
How To Sterilize Liquids
Infection Control: Sterilization Instrument Trays
Instrument Cleaning
Introducing DuraCleanse Hands-Free Sanitizer Dispenser - Say No to leaky sanitizers and Save Money!
Is Your Instrument Washer Cleaning Effectively? Can You Prove It? Are Your Patients and Staff At Risk?
NEW Instrument Washer Disinfector Steelco DS 500 CL
Patient recovery: The importance of human connection
SteriData Logger Paperless Sterilizer Cycle Printer
Thermometers for Schools
Tuttnauer Autoclaves - Spec Sheet
Water Distillers - The Best Choice for Clean, Chemical & Mineral Free Water
What Is an Ultrasonic Cleaner?
What is the difference between a Face Shield and a Face Mask?
Why Sterilizer Record Keeping Is Important
PAPR vs. N95
Respirators
N95 Respirators Surgical Face Masks In Stock Same Day Shipping
AeroWipe™ Multipurpose Wipes and AeroCleanse™ Hand Sanitizer Moisturizing Gel
Glossary
How to Use RapidHeat Sterilizers
How To Wrap Instruments for RapidHeat Sterilization
Monitoring
STERILIZER TYPE
Steam
Biological Indicators
Dry Heat
EtO Gas
Plasma
PRODUCT TYPE
Biological Indicators
Sterilizer Monitoring results is minutes! 20 min. Biological Indicators
Bowie Dick Tests
Indicator Tape
Readers & Incubators
Chemical Indicators
Ultrasonic Monitors
Wash Monitors
Process Challenge Device
Services & Repairs
Autoclave Repair | PM Service
Clean to Sterile Solutions
What Sets Us Apart
Customer Reviews
About Us
Contact
Rent Autoclave / Equipment Rental
Lease Autoclave / Equipment Financing
Autoclave Trade-In
Autoclave Preventative Maintenance
Autoclave Service
AutoShip
Preventative Maintenance Kits
Tuttnauer Autoclave PM Kits
Sterilizer Cleaning Services
Training
Lease Calculator
Sale
Rent
Finance
Brands
Industry
Catalog
Manuals
Home
>
Sale on New SciCan Equipment
>
New Scican Statim G4 5000 Cassette Autoclave with $300 Rebate
Price:
$
7,327.00
Additional Discount with Trade-In
Product Code:
NSS5000G4-REBATE
Qty:
Description
Technical Specs
Literature
New Scican Statim 5000 G4 Cassette Sterilizer with
$300 Manufacture Rebate
when purchased by June 30, 2023
Save more with trade-in! Just email a picture to
[email protected]
and we will send you discount
FAST:
STATIM's unmatched speed and dependability have made STATIM the world's best-selling autoclave. And its patented gentle technology has made STATIM the world's favorite.
FORWARD:
The STATIM G4 will offer you a level of interactivity never seen before. The STATIM G4, through its LCD touch screen control and STATIM Live networking capability, has been designed to provide you with unprecedented ease of use and puts the user in total control.
SciCan's innovative G4 Technology, now WiFi enabled, automatically records and monitors every cycle 24/7 so the tedious task of manually logging cycle data can now be done automatically and error-free. Logging accurate cycle information has never been so effortless, simple and efficient. STATIM G4 Technology detects human or mechanical error before it costs time and money.
Benefits of the G4 network:
Monitoring real-time cycle data
Instant data logging
Proactive maintenance management
Automatic system updates to your G4 machines
Features of the Statim G4 5000:
Immediate Steam Generation - Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a steam generator, rapidly heated and converted to steam in mere seconds.
Air Removal - Using PPPD technology and our patented steam injection process“ air is automatically forced out of the sterilization chamber
Cassette System - The thin stainless steel walls of STATIM™s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave
Drying Technology - The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying
Touch - A large 3.5†high-resolution touchscreen offers a vivid display of messages, current cycle information and customizable colours all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-centre
Connect - Through your networked portal, you can view not only your STATIMs current operations in real time, you can also access cycle history, printing and validation information, and also sterilization records. Capable of sending emails with cycle information errors directly to your dealer, your STATIM G4 will let qualified technicians know when service is imminent
Protect - Patient safety relies on attention to detail. The STATIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle. This encourages extra attention to process and creates a safer environment for both staff and patients
Collect - An undocumented sterilization cycle might as well not have been performed. With each cycle, information must be stored to protect your office and your patient. The integrated DataLogger stores all cycle information for the lifetime of the unit, which is accessible through multiple channels such as: a USB port for manual retrieval; an Ethernet connection for web based archiving or desktop printing; or a RS232 port for an external printer option.
WARRANTY: 12 months parts and labor
Controls: Automatic
Dimensions (L x W x H): 23.6” x 16.1” x 7.5”
Cassette internal dimensions: 15” x 7” x 3”
Cassettes: 1
Voltage: 115V, 50/60 Hz, 15A / 1450 W
Weight without water: 73 lbs (33 kg)
Description
Sterilization Temperature
Sterilization Time
Total Cycle Time
Unwrapped Instruments
270° F
3.5 min
9 min
Wrapped Instruments
270° F
6 min
17.5 min
Rubber, plastic
250° F
35 min
45 min
Heavy Duty Unwrapped / Air Drying
270° F
6 min
12 min
Scican Statim G4 Cassette Sterilizer Brochure
Scican Statim G4 Operators Manual
Features
Your browser does not support the video tag.
Share your knowledge of this product.